Photon Factory

KEK

BL-15A2 : High-brilliance Small Angle X-ray Scattering

Overview

Beamline group Subcommittee 5 (Small Angle X-ray Scattering)
Techniques
  • Hard X-ray small-angle scattering
  • Hard X-ray small-angle/wide-angle scattering
  • Grazing-incidence Hard X-ray small-angle scattering
  • Grazing-incidence Hard X-ray small-angle /wide-angle scattering
  • Tender X-ray small-angle scattering
  • Grazing-incidence Tender X-ray small-angle scattering
  • Tender X-ray ultra small-angle scattering
Features
  • Tender X-rays (2.1 - 5 keV) are available.
  • Multipurpose SAXS beamline
  • Max. camera length : 3.5 m (Hard X-ray)
  • Camera length: 0.83 or 6.6 m (Tender-X-ray)
  • Max. SAXS resolution : ~ 500 nm @ 5.7 keV
    : > 1300 nm @ 2.1 keV
Area of research
  • Soft matter science (polymer, fiber, lipid, liquid crystal, food, etc.)
  • Biophysics/Structure Biology
  • Material Science
Contacts
  • Manager : Hideaki TAKAGI takagih(at)post.kek.jp
  • Sub : Nobutaka SHIMIZU nobutaka.shimizu(at)kek.jp
  • Sub : Noriyuki IGARASHI noriyuki.igarashi(at)kek.jp
  • Please change (at) to @ in the e-mail address.
Special notes
  • In SAXS experiments using Tender X-rays, the sample chamber is under vacuum state.

Performance

Source
  • 2.5GeV PF Short Gap uUndulator
Optics
  • Monochtomator (Fix-exit double crystal Si(111), liquid nitrogen cooling)
  • Horizontal collimation bent flat mirror (Rh coated)
  • Horizontal focusing double 16-element bimorph mirror (Rh coated)
  • Vertical focusing bent flat mirror (Rh coated)
  • Double flat mirror (Ni coated) for higher harmonics reduction: using Tender X-ray

Configuration of BL-15A2
Energy range
  • 2.1 - 15 keV (0.93 - 5.9 Å)
Resolution (ΔE/E)
  • 2 x 10-4
Beam size
  • H 0.55 x V 0.09 mm2 at a sample position in camera length of 1.5 m.
  • H 0.29 x V 0.04 mm2 at a sample position in Tender X-ray SAXS experiments.
Photon flux
  • 2 x 1011 photons/s @ 10.2 keV
Instruments
  • Camera length:0.25, 0.5, 1.5, 2.5, 3.5 m(SAXS)
  • Camera length:0.95, 1.2, 2.2, 3.2 m (When using WAXS chamber)
  • PD embedded beam stopper/GISAXS beam stopper
  • Delay pulse generator
  • Chiller for sample temperature adjustment (5 - 70 °C)
  • Incubator (3 - 45 °C)
  • Block incubator (4 – 100 &Cring;、1.5ml, 0.5 ml tube)
  • Microcentrifuge (1.5, 0.5 ml, -20 – 40 °C)
  • Perista pump
  • Sample solution flow system for mitigating the effect of radiation damage.
  • Rotary Sample Changer (36 samples)
  • HPLC system for SEC-SAXS
  • Microspectrophotometer (~ 2 μL)

SAXS experiments using Hard X-rays


SAXS experiments using Tender X-rays


USAXS experiments using Tender X-rays

【Common instruments:BL-6A、BL-10C、BL-15A2】
  • General GISAXS stage
  • Heating/Cooling stage:10002L(Linkam scientific、-190 - 600 °C), HSC302-LN190(Instec、-190 - 400 °C)
  • One-dimensional tensile tester (ISUT-2207、IS GIKEN)
  • DSC stage(AA1712-1303、Rigaku)
Detectors
  • SAXS : PILATUS3 2M (DECTRIS AG)
  • 1D WAXS : PILATUS3 300K-W (DECTRIS AG)
  • 2D WAXS : PILATUS 300K (DECTRIS AG) *Under installation
Remote / Mail-in
  • Remote experiment using some instruments is available (Please consult with beamline contact person).
Special notes
  • A flat card detector (C9728DK-10, Hamamatsu Photonics) is also available as a 2D WAXS detector.

More information

References

  1. Takagi, H., Igarashi, N., Nagatani, Y., Ohta, H., Mori, T., Kosuge, T. and Shimizu, N., AIP Conf. Proc., 2054, 060038 (2019), doi:10.1063/1.5084669[Hard X-ray Setting]
  2. Takagi, H., Igarashi, N., Mori, T., Saijo, S., Nagatani, Y., Ohta, H., Yamamoto, K. and Shimizu, N., J. Appl. Phys., 120, 142119 (2016), doi:10.1063/1.4961977[Tender X-ray Setting]
  3. Igarashi, N.,Shimizu, N., Koyama, A., Mori, T., Ohta, H., Niwa, Y., Nitani, H., Abe, H., Nomura, M., Shioya, T., Tsuchiya K. and Ito, K., J. Phys.: Conf. Ser., 425, 072016 (2013), doi:10.1088/1742-6596/425/7/072016[Old]

Publications

KEK-PF Publication Database (Publications of BL-15A2)

Last updated: 2021-11-29