BL-11D : Characterization of Optical Elements used in the VSX region

The current BL-11A, BL-11B and BL-11D will be shut down at the end of FY2022 due to the construction of a multi-function R&D beamline. The activities of these beamlines will be continued at the new BL-12A (scheduled to start in late FY2023) and the existing beamlines. For more information, see Reconstruction of BL-11 and BL-12.

Overview

Beamline group Subcommittee 1 (Photoelectron Spectroscopy)
Techniques
  • Reflectometry
  • Auger electron - photoelectron coincidence spectroscopy
Features
  • The photon-energy ranges available at BL-11D is 60−900 eV for the horizontal linear polarized light.
  • A reflectometer is equipped at BL-11D.
  • An Auger electron – photoelectron coincidence spectrometer is available for use.
  • You can install your own apparatus to BL-11D to conduct your experiment.
Area of research
  • Evaluation of optical elements
  • Evaluation of soft X-ray detectors
  • Surface science
Contacts
  • Kazuhiko MASE mase(at)post.kek.jp
  • Please change (at) to @ in the e-mail address.
Notes
  • The beamline can be selectively used with the other beamlines covering similar energy ranges (Undulator: BL-2A/B, 13A/B,16A, 19A/B,28A/B, Bending magnet: BL-7A, 11A), so please consult with the contact person for the request.

Performance

Source
  • 2.5GeV PF Bending magnet (B11)
Optics
  • Variable-included-angle monochromator with spherical gratings(an entrance slit,focusing mirrors,plane mirror spherical gratings,and an exit slit)
  • 2 focusing post-mirrors (an elliptic mirror for the vertical focusing and an elliptic mirror for the horizontal focusing)


Energy range
  • 200 - 900 eV (G1), 60 - 245 eV (G3)
Resolution (ΔE/E)
  • 1/2000 (G3, Slits 200 μm x 100 μm)
Beam size
  • Typical beam size at a sample position in the reflectometer : 1 mm (H) x 0.1 mm (V)
Photon flux
  • 1.2 x 1010 photons/s (G3, Slits 200 μm x 100 μm, 130 eV)

Instruments
  • A eflectometer
    The incidence angle varies between 5 and 89 degrees. The angular resolution < 0.1° in reflectivity measurements is available. A sample of φ200 mm can be mounted on the sample stage. It is also possible to place multiple small samples on the stage. The ultimate vacuum of the reflectometer chamber is 1 × 10-5 Pa.

  • An Auger electron - photoelectron coincidence spectrometer
    The Auger electron – photoelectron coincidence spectrometer can be installed downstream of the reflectometer mount by sliding the reflectometer to the BL-10 side to install the beam duct. For more information, please contact the person in charge.

Detectors
  • Soft X-ray detector
Remote / Mail-in
  • not available
Special notes
  • Users are permitted to bring in their own apparatus to BL-11D. The pressure at the connecting chamber to the BL should be under 10-6 Pa

References

  1. Photon Factory Activity Report 1997, 15, A101 (1997), https://www2.kek.jp/imss/pf/science/publ/acr/archive/PF_Act_Rep_1997_15XRA.pdf : [Beamline]

Publications

KEK-PF Publication Database (Publications of BL-11D)