BL-16A : Variable Polarization (Fast Switching) Soft X-ray Spectroscopy Station

Beamline group Group 1 (Soft X-ray Spectroscopy)
Techniques
  • Soft X-ray Magnetic Circular & Linear Dichroism
  • Soft X-ray Spectroscopy
Features
  • Right and left circular polarizations, as well as horizontal and vertical linear polarizations, are available.
  • Fast polarization switching (10 Hz) is available between two different polarizations.
  • 1.2 and 5 T soft X-ray magnetic circular polarization apparatus are installed for public use.
  • Free ports are available, to which users can bring their own apparatus.
Area of research
  • Magnetic Thin Films
  • Surface Science
  • Solid-state Physics
Contacts
  • Kenta AMEMIYA kenta.amemiya(at)kek.jp
  • Please change (at) to @ in the e-mail address.
Special notes
  • Similar energy region is covered by other stations (Undulator: BL-2A/B, 13A/B, 19A/B, Bending Magnet: BL-7A, 11A, 11D).

Performance

Source
  • 2.5GeV PF, Twin APPLE-II Undulators
Optics
  • Variable-Included-Angle Varied-Line-Spacing Plane Grating Monochromator
  • Post focusing system with a toroidal mirror
Energy range
  • Mainly 400 - 1500 eV
Resolution (ΔE/E)
  • ~ 2 × 10-4
Beam size
  • 200 - 500 μm (H) x 50 - 100 μm (V)
Photon flux
  • ~ 1011 photons/s

Calculated photon flux at a certain resolution (E/ΔE)
Instruments
  • Soft X-ray Magnetic Circular Dichroism (1.2 and 5 T)
  • Depth-resolved Soft X-ray Absorption Spectroscopy
Detectors
  • Drain current, Microchannel plate, Silicone Drift Detector, and Soft X-ray CCD camera (depending on apparatus)
Remote / Mail-in
  • available
Special notes
  • Sample size : <~10 mm square is recommended
  • Users instruments : acceptable
  • Beam height : ~ 1217 mm from the floor,Pressure : <10-4 Pa

Plan view of the experimental area

References

  1. K. Amemiya and T. Ohta, J. Synchrotron Rad., 11, 171 (2004), doi:10.1107/S0909049503023598 : [Monochromator]
  2. K. Amemiya et al., AIP Conf. Proc., 1234, 295 (2010), doi:10.1063/1.3463193 : [Beamline]
  3. K. Tsuchiya et al., J. Phys.: Conf. Ser., 425, 132017 (2013), doi:10.1088/1742-6596/425/13/132017 : [Pollarization switching (Light source)]
  4. K. Amemiya et al., J. Phys.: Conf. Ser., 425, 152015 (2013), doi:10.1088/1742-6596/425/15/152015 : [Pollarization switching (Beamline)]
  5. K. Amemiya, Phys. Chem. Chem. Phys., 14, 10477 (2012), doi:10.1039/C2CP41085K : [Depth-resolved Soft X-ray Absorption Spectroscopy]
  6. M. Sakamaki and K. Amemiya, Rev. Sci. Instrum., 88, 083901 (2017), doi:10.1063/1.4986146 : [Depth-resolved Soft X-ray Absorption Spectroscopy by fluorescence-yield]

Publications

KEK-PF Publication Database (Publications of BL-16A)

Last updated: 2021-8-23